| | | AT810 LCR Meter | | ● | Measurement parameter: L,C,R,Z,D,Q,θ(deg),θ(rad) | | ● | Measurement frequency: 100Hz, 120Hz, 1kHz, 10kHz | | ● | Measurement Level: 0.1V, 0.3V, 1.0V | | ● | Measurement Speed: 2times/second, 5times/second, 15times/second | | ● | Basic Accuracy: 0.1% |
| | 3rd Edition |
|
| | | AT811 LCR Meter | | ● | Measurement parameter: L,C,R,Z,D,Q | | ● | Measurement frequency: 100Hz, 120Hz, 1kHz,10kHz | | ● | Measurement Level: 0.3V,1V | | ● | Measurement Speed: 2times/second, 5times/second | | ● | Basic Accuracy: 0.2% |
| | |
|
| | | AT816A LCR Meter | | ● | Measurement parameter: L,C,R,Z,D,Q,θ(deg),θ(rad),Vm,Im | | ● | Measurement frequency: 50Hz~200kHz (24064 points) | | ● | Measurement Level: 0.01V~2.00V programming | | ● | Measurement Speed: 4times/second, 9times/second, 25times/second | | ● | Basic Accuracy: 0.05% |
| | |
|
| | | AT2816A LCR Meter | | ● | Measurement parameter: L,C,R,Z,D,Q,θ(deg),θ(rad),Vm,Im | | ● | Measurement frequency: 50Hz~200kHz (24064 points) | | ● | Measurement Level: 0.01V~2.00V programming | | ● | Measurement Speed: 3times/second, 6times/second, 10times/second,30times/second | | ● | Basic Accuracy: 0.05% |
| | |
|
| | | AT2816B LCR Meter | | ● | Measurement parameter: L,C,R,Z,D,Q,θ(deg),θ(rad),Vm,Im | | ● | Measurement frequency: 50Hz~200kHz (37points) | | ● | Points:50Hz,60Hz,80Hz,100Hz,120Hz,150Hz,200Hz,250Hz,300Hz,400Hz,500Hz,600Hz,800Hz,1kHz,1.2kHz,1.5kHz,2kHz,2.5kHz,3kHz,4kHz,5kHz,6kHz,8kHz,10kHz,12kHz,15kHz,20kHz,25kHz,30kHz,40kHz,50kHz,60kHz,80kHz,100kHz,120kHz,150kHz,200kHz | | ● | Measurement Level: 0.01V~2.00V programming |
| | |
|
| | | AT817 LCR Meter | | ● | Measurement parameter: L,C,R,Z,D,Q,θ(deg),θ(rad) | | ● | Measurement frequency: 50Hz~100kHz (10 points) | | ● | Measurement Level: 0.1V,0.3V,1.0V | | ● | Measurement Speed: 3times/second, 8times/second, 20times/second | | ● | Basic Accuracy: 0.05% |
| | |
|
| | | AT2817A Precision LCR Meter | | ● | Measurement parameter: L,C,R,Z,D,Q,θ(deg),θ(rad),Vm,Im | | ● | Measurement frequency: 50Hz~100kHz (16 points) | | ● | Measurement Level: 0.01V~2.00V programming | | ● | Measurement Speed: 4times/second, 9times/second, 30times/second | | ● | Basic Accuracy: 0.05% |
| | |
|
| 
| | AT2818 Precision LCR Meter | | ● | Measurement parameter: L,C,R,Z,D,Q,θ(deg),θ(rad),Vm,Im | | ● | Measurement frequency: 10Hz~300kHz (120000 points) | | ● | Measurement Level: 0.01V~2.00V programming | | ● | Measurement Speed: 3times/second, 6times/second, 10times/second,30times/second | | ● | Basic Accuracy: 0.05% |
| | |
|
| | | AT820 LCR Meter | | ● | Measurement parameter: L,C,R,Z,D,Q | | ● | Measurement frequency: 100Hz, 120Hz, 1kHz | | ● | Measurement Level: 0.3V | | ● | Measurement Speed: 2.5 times/second | | ● | Basic Accuracy: 0.25% |
| | |
|
| | | AT821 LCR Meter | | ● | Measurement parameter: L,C,R,Z,D,Q,Automatic | | ● | Measurement frequency: 100Hz, 120Hz, 1kHz, 10kHz | | ● | Measurement Level: 0.3V | | ● | Measurement Speed: 2.5times/second | | ● | Basic Accuracy: 0.25% |
| | |
|
|